Technical data
| Attributes | |
| ARTICLE | WRA-M46-1 |
| POWER | 34.2 kWh/24h |
| SIZE L/W/H | 711/ 1254/ 828mm |
| VOLTAGE | 220-240V |
| Temperature | -5/+15°C |
| WEIGHT | 92kg |
| Model | 68310 |
| COLOR | White RAL9003 |
| NOTES | Refregirant (type/gr) - R290/2x150 |
-5 to +15 °C
A monoblock cooler unit combines compressor, condenser and evaporator in one sealed assembly that mounts directly onto the wall of a walk-in chiller or cold-room. Instead of separate indoor and outdoor sections linked by refrigerant lines, the entire refrigeration circuit is contained in a single weatherproof housing. This design eliminates on-site refrigerant charging, reduces installation time and keeps the cooling system compact. The unit draws heat from the air inside the cold-room and expels it outside, maintaining the set temperature without needing a separate machine room.
The operator fits the unit to the external wall of the cold-room, connects the power supply and sets the desired temperature on the digital controller. Once switched on, the ventilated cooling system circulates air across the evaporator coil inside the cold-room, removing heat and lowering the temperature. The controller displays the current temperature and adjusts the compressor and fans to hold the set point between -5 °C and +15 °C. If multiple units are installed, they can be linked in series to share the cooling load across larger cold-rooms.
The housing is finished in white RAL9003 and sized to fit panels up to 200 mm thick. A ventilated cooling system ensures consistent airflow across the condenser, while the refrigerant R290 (propane) is used in two 150 g charges. The digital controller provides temperature readout and adjustment, with no additional controls named.
The voltage range of 220-240 V matches standard single-phase UK commercial circuits, allowing the unit to be plugged into existing kitchen power points without special wiring. The weight of 92 kg indicates that two people or a small trolley are needed to position the unit during installation. The footprint of 711 mm by 1254 mm determines the wall space required on the outside of the cold-room, while the 34.2 kWh per 24 hours energy rating reflects the electrical load the unit will place on the supply.
Cleaning is limited to the external housing and condenser coil; the sealed refrigeration circuit requires no user maintenance. The unit is supplied as a single variant, the WRA-M46-1, and is designed for use with walk-in chillers and cold-rooms constructed from panels up to 200 mm thick.
Catalogued under monoblock cooler units for professional refrigeration systems.