More from this brand
Technical data
| Attributes | |
| ARTICLE | PEG98T100I |
| POWER | 21 kW |
| SIZE L/W/H | 800/ 900/ 700 mm |
| VOLUME | 100 l |
| WEIGHT | 138 kg |
Indirect heating
A gas boiling pan heats water in an interspace jacket that surrounds the cooking tank. The low-pressure steam generated in this jacket transfers heat evenly across the entire surface of the tank, eliminating hot spots and scorching. This indirect method keeps the cooking temperature steady and gentle, making it suitable for stocks, sauces and large batches of vegetables or pasta without stirring.
The operator fills the tank with the required liquid or ingredients, then opens the gas supply. A piezo-electric spark ignites the pilot flame, which is monitored by a thermocouple safety device. Once the pilot is stable, the main burner lights and begins heating the interspace water. The front-panel water-level viewer lets the operator check the jacket fill without opening the lid. A hot-and-cold swivel tap mounted on the worktop provides instant water for topping up or cleaning. When the cooking cycle is complete, the gas valve is closed and the contents are drained or ladled out.
The tank sides and jacket are constructed from AISI 304 stainless steel, while the tank bottom is AISI 316 for extra corrosion resistance. A standard AISI 304 lid reduces steam and heat loss; an optional double-insulated lid is available for improved thermal retention. The gas burner is a stainless-steel tubular unit with a self-stabilising flame, and a safety valve with pressure gauge is fitted to the gas line.
A 21 kW power rating means the unit requires a dedicated gas supply capable of delivering the full load without pressure drop. The 100 L volume allows large batches to be prepared in a single cycle, reducing the number of refills during service. The 800 × 900 × 700 mm footprint determines the space it occupies on the worktop or stand, while the 138 kg weight indicates that it must be positioned on a sturdy, load-bearing surface and is not easily moved once installed.
Cleaning involves draining the tank, wiping the interior with a non-abrasive cloth and mild detergent, and rinsing through the swivel tap. The interspace jacket should be flushed periodically to remove scale, using the front viewer to confirm the water level. The gas burner and pilot assembly require occasional inspection for blockages, and the thermocouple safety device should be tested to ensure it shuts off the gas if the flame fails.
An optional double-insulated lid can be specified for better heat retention. The unit is listed in the catalogue under gas boiling pans, professional catering equipment, and large-capacity cooking vessels.